background image

Control Registers

Chapter 13 Serial Interface 4

XIII - 7

14

14

„

Serial interface 4 Status Register (SC4STR)

Figure 13-2-5 Serial interface 4 Status Register (SC4STR : x'03FAC', R)

0

1

2

4

5

6

7

3

( At reset: X X X X X X X X)

SC4STR

SLVBSY

RSTRT

STRT

I2CINT

WRS

0

1

Undetected

ACK detection flag

Detected

ACKVALID

0

1

Slave

Master

Data transfer direction
determination flag

Master

Slave

WRS

I2CBSY

ACKVALID

-

0

1

Other than during data transfer

Slave busy flag

During data transfer

SLVBSY

0

1

Bus free status

Bus busy flag

Bus busy status

I2CBSY

0

1

Re-start condition detection

RSTRT

0

1

Start condition detection

STRT

0

1

Undetected

Interrupt detection flag

Detected

I2CINT

Undetected

Detected

Undetected

Detected

Advertising