Xi - 28 – Panasonic MN101C77C User Manual

Page 354

Advertising
background image

Chapter 11 Serial Interface 0, 1

XI - 28

Operation

Figure 11-3-5 Transmission Timing (falling edge, start condition is enabled)

Figure 11-3-6 Transmission Timing (falling edge, start condition is disabled)

„

Trasnmission Timing

T

Clock
(SBT pin)

Output data
(SBOpin)

SCnTBSY

Interrupt
(SCnTIRQ)

Transfer bit counter

0

1

2

3

4

5

6

7

(Write data to TXBUFn)

(at master)

Tmax=1.5 T

(at slave)

Tmax=2T

(at master)

Tmax=T

T

Clock
(SBT pin)

Output data
(White SBO pin)

SCnTBSY

Interrupt
(SCnTIRQ)

Transfer bit counter

0

1

2

3

4

5

6

7

(Write data to TXBUFn)

(at master)

Tmax=2.5 T

(at slave)

Tmax=2 T

(at master)

Tmax=T

Advertising
This manual is related to the following products: