Chapter 12 Serial Interface 3

Operation

XII - 39

(19) Judge the ACK bit level.

SC3CTR (x'3FAA')

bp0 : SC3ACKO

(20) Select the transfer bit count.

SC3MD0 (x'3FA8')

bp2-0 : SC3LNG2-0 = 0

(21) Select the start condition.

SC3MD0 (x'3FA8')

bp3 : SC3STE = 0

<The next data transmission is started.>

(22) Serial transmission is started. [

(17)]

<The transmission is finished.>

<Transaction after IIC communication>

(23) Clear BUSY flag.

SC3CTR (x'3FAA')

bp7 : IICBSY = 0

(19) Confirm the level of the ACK bit, received by the

SC3ACKS flag of the serial 3 control register

(SC3CTR). When SC3ACKO = 0, the transmission

is continued. When SC3ACKO = 1, the reception at

slave may be impossible, finish the communication.

(20) If the transfer bit count is changed, set the

transfer count bit by the SC3LNG2-0 flag of the

serial 3 mode register (SC3MD0).

(21) Set the SC3STE flag of the SC3MD0 register to "0"

to disable start condition.

(22) Set the transmission data to SC3TRB to start the

transmission. [

(17)]

(23) Clear the IICBSY flag of the serial 3 control

register (SC3CTR) to "0". Then, the stop condition

is automatically generated to finish the

communication.

Note : In the above (5) to (8), (9) to (12), (13) to (14), (15) to (16), (18) to (19) and (20) to (21), settings can

be set at once.

Setup Procedure

Description