XI - 11

Chapter 11 Serial Interface 0, 1

Control Registers

„Serial Interface 0 Mode Register 3 (SC0MD3)

All flags are only for reading.

Figure 11-2-6 Serial Interface 0 Mode Register 3 (SC0MD3 : x'03F95', R)

0

1

2

4

5

6

7

3

(At reset : 0 0 0 0 0 0 0 0 )

SC0MD3

SC0ERE

SC0ORE

SC0PEK

SC0FEF

SC0REMP

SC0TEMP

SC0RBSY

SC0TBSY

0

1

No error

Error monitor flag

Error

SC0ERE

0

1

No error

Overrun error detection

Error

SC0ORE

0

1

No error

Parity error detection

Error

SC0PEK

0

1

No error

Framing error detection

Error

SC0FEF

0

1

Empty

Receive buffer empty flag

Full

SC0REMP

0

1

Empty

Transfer buffer empty flag

Full

SC0TEMP

0

1

Other use

Serial bus status

Serial reception in progress

SC0RBSY

0

1

Other use

Serial bus status

Serial transmission in progress

SC0TBSY