Operation

Chapter 15 A/D Converter

XV - 15

(7)

Enable the interrupt by setting the ADIE flag of

the ADICR register to "1".

(8)

Set the ANLADE flag of the A/D converter

control register 0 (ANCTR0) to "1" to send a

current to the ladder resistance for the A/D

conversion.

(9)

Set the ANSTSEL flag of the A/D converter

control register 2 (ANCTR2) to "1", and select

"writing to the ANST flag of the A/D converter

control register 3 (ANCTR3), the external

interrupt 3"as the A/D converter activation

factor.

(10) When the external interrupt 3, set in (5) is

generated, the ANST flag of the A/D converter

control register 2 (ANCTR2) is set to "1" to start

the A/D conversion. And even if the external

interrupt 3 is not generated, the A/D conversion

is started by setting the ANST flag of the A/D

converter control register 2 (ANCTR2) to "1".

(11) When the A/D conversion is finished, the A/D

conversion complete interrupt is generated,

and the ANST flag of the A/D converter control

register 2 (ANCTR2) is cleared to "0".

The result of the conversion is stored to the A/D

converter buffer (ANBUF0, 1).

Setup Procedure

(7)

Enable the interrupt.

ADICR (x'3FFA')

bp1 : ADIE = 1

(8)

Set the A/D ladder resistance.

ANCTR0 (x'3FB0')

bp3 : ANLADE = 1

(9)

Select the A/D converter activation

factor.

ANCTR2 (x'3FB2')

bp6 : ANSTSEL = 1

(10) Start the A/D conversion.

ANCTR2 (x'3FB2')

bp7 : ANST = 1

(11) Complete the A/D conversion.

Description

Note : The above (3) to (4) can be set at once.

Even if the external interrupt 3 is generated during A/D conversion, the A/D converter is

operated in normal.

Also, once the A/D conversion is finished, it is never started again.