Chapter 12 Serial Interface 3

Operation

XII - 33

Figure 12-3-17 Master Reception Timing

„

Master Reception Timing

SDA

SCL

Interrupt

1

2

. .

. .

8

ACK

1

2

8

IICBSY

Set data to SC3TRB

Clear IICBSY flag

(1)

(2)

(3)

(4)

(5)

(6)

Set data to SC3TRB

ACK

8-bit

transmission

8-bit

reception

[Set dummy data]

(1) Output start condition.

(2) Bus released period, ACK bit is received.

(3) Interrupt transaction

- Setup for the reception mode : SC3REX = 0

1

- Disable start condition : SC3STE = 1

0

- Start communication : set data to SC3TRB.

(4) Output ACK bit.

(5) Bus released period, interrupt transaction

- Complete communication : clear IICBSY flag

(6) Generate stop condition.