Panasonic MN101C77C User Manual

Page 259

Advertising
background image

VI - 45

Chapter 6 8-bit Timers

Remote Control Carrier Output

Setup Procedure

Description

(6)

Select the normal timer operation.

TM0MD (x'3F54')

bp4

: TM0PWM = 0

bp5

: TM0MOD = 0

(7)

Select the count clock source.

TM0MD (x'3F54')

bp2-0

: TM0CK2-0 = 000

(8)

Set the base cycle of remote control

carrier.

TM0OC (x'3F52')

= x'6C'

(9)

Start the timer operation.

TM0MD (x'3F54')

bp3

: TM0EN

= 1

(10) Enable the remote control carrier

output.

RMCTR (x'3F6E')

bp3

: RMOEN

= 1

(6)

Set both of the TM0MOD flag and TM0PWM

flag of the TM0MD register to "0" to select

normal timer operation.

(7)

Select fosc to clock source by the

TM0CK2-0 flag of the TM0MD register.

(8)

Set the base cycle of remote control carrier by

writing x'6C' to the timer 0 compare register

(TM0OC). The set value should be (8 MHz/

73.4 kHz) - 1 = 108(x'6C')

8 MHz is divided to be 73.4 kHz, 2 times

36.7 kHz.

(9)

Set the TM0EN flag of the TM0MD register to

"1" to stop the timer 0 counting.

(10) Set the RMOEN flag of the RMCTR register to

"1" to enable the remote control carrier output.

TM0BC counts up from x'00'. Timer 0 outputs the base cycle pulse set in TM0OC. Then, the 1/3 duty

remote control carrier pulse signal is output. If the RMOEN flag of the RMCTR register is set to "0",

the remote control carrier pulse signal output is stopped.