14-3-12 Transfer Mode 7

In transfer mode 7, ATC1 automatically transfers one byte of data two times every time an ATC1 activation

request occurs.

(1)

(2)

(3)

AT1MAP0

AT1MAP0 + 1

AT1MAP0 + 2

AT1MAP0 + 3

Memory Pointer 0

00000 - 3FFFF

03F00 - 03FFF

Memory Pointer 1

(Only lower

8 bits are valid)

AT1MAP1

In this mode the transfer direction indicated by memory pointers 0 and 1 reverses for the second data

byte transfer.

In the first data byte transfer, the I/O space address (x'03F00' - x'03FFF') in memory pointer 1 is the

source address, and the address in memory pointer 0, for any memory space, is the destination address.

When the first data byte transfer ends, the address in memory pointer 0 increments by one.

In the second data byte transfer, the incremented address in memory pointer 0 becomes the source

address, and the I/O space address (x'03F00' - x'03FFF') in memory pointer 1 becomes the destination

address. The address in memory pointer 0 remains unchanged after the second data byte transfer ends.

Set the I/O address in lower 8 bits of memory pointer 1 (AT1MAP1L). The upper 10 bits of the I/O space

address (x'03F') need not to be set in AT1MAP1H, AT1MAP1M.

Figure 14-3-9 Transfer Mode 7

Transfer mode 7 can be used to support continuous transmission/reception for serial inter-

face 3. Set memory pointer 1 to point to the serial transmission/reception shift register

(SCnTRB) and select serial interrupts as an ATC1 trigger factor. In this way, each time a

serial communication ends the MCU continuously reads the reception data (first data byte

transfer) then writes the transmission data (second data byte transfer) up to 255 times,

entirely through the hardware.