2 commands sent by the host, 2-1 displaying the screen, Display specified screen – Omron NT-series Programmable Terminal V022-E3-1 User Manual

Page 222

Advertising
background image

Note

Reference



    &

Section 6-2

7-2

Commands Sent by the Host

The operating commands sent by the Host are described below.

All data values must be sent in ASCII code.

Example:

m

1

m

2

d

1

d

2

d

1

35

41

31

32

33

2-bit hexadecimal

5A

H

3-bit BCD

123

7-2-1

Displaying the Screen

This section describes the procedure for screen display by the Host and also that
for checking the displayed screen. For details on the screen display function of the
NT600S, refer to 5-2 Outline of Functions (page 119) and 5-3 Screen Display
(page 124).

Switching the Display Screen

By sending a command from the Host, the specified screen is displayed.

If a screen number is specified by the Host using the following command, the dis-
play screen is switched to the corresponding screen (screen number: 1 to 1000).
Screen number 0 is a white screen (no display).



Continuous screens and overlapping screens

- To display continuous screens or overlapping screens, it is necessary to speci-

fy a parent screen. If a child screen is specified, only the specified screen is
displayed.

For continuous screens and overlapping screens, refer to 5-3 Screen Display
(page 124).

Display Specified Screen

Format

1B

[ESC]

30

0

m

1

m

2

 

 

m

3

 

m

4

 

m

1

m

2

m

3

m

4

:

Number of displayed screen (4-digit hexadecimal)
0000: No display
0001 to 03E8

H

: Screen #1 to #1000

Description

The specified screen is displayed on the NT600S when a screen number is sent
from the Host with this command.