Note



.   .(          $0&

Appendix E

Connector Cover Assembly

Assemble the connector covers as shown in the diagram below.

End connected to FG

Aluminum foil tape

End not connected to FG

Preparing RS-232C Connector Cables

Prepare a connector cable to connect a NT600S to a HOST separated by more than 5 m so that the supplied con-
nector cable (XW2Z-500P) cannot be used. The maximum cable length is 15 m.

Recommended Parts

Name

Model

Remarks

Connector

XM2A-0901

9-pin, manufactured by OMRON

Connector cover

XM2S-0911

9-pin, manufactured by OMRON

Cable

AWG28



5P

IFVV-SB

Multicore cable, manufactured by Fujikura, Ltd.

CO-MA-VV-SB
5P



28AWG

Multicore cable, manufactured by Hitachi Cable, Ltd.

On the other end of the cable use the type of connector and connector cover which matches the host computer
connector type.

Connection For Host

Only the shielded wire on the host side is connected to the connector hood. The
following diagram is for RS/CS control. If RS/CS control is not executed, RS and
CS must be short-circuited (turned over) for both the NT600S and host side.

1

2

3

4

5

6

7

8

9

Pin
number

Abbrevi-
ation

FG

SD

RD

RS

CS

+5V

--

--

SG

RS-232C
interface

Shielding
wire

NT600S

HOST

RS-232C
interface

Pin
number

Abbrevi-
ation

1

2

3

4

5

6

7

--

RD

SD

--

SG

--

RS

8

CS

For some host computers the combination of pin numbers and signal names may
differ from those shown in the diagram above. Refer to the Host instruction manu-
al before wiring the connector.