Section 2-7

Removing the unit

As shown in the figure below, grasp the unit by the cutouts at either side, then pull it
out while keeping a firm grip.

C200H Interface Unit Switch Settings

Set all the DIP switches (SW1, SW2) of the C200H interface unit to “OFF” (re-
served for system use) and set the unit number to 0 with the rotary switch (SW3).

It is necessary to set a machine number for NT600S since it operates as a high-
level function I/O unit of C200H. Make sure that the machine number to be allo-
cated is unique.

Switch cover

The DIP switches are located under the switch cover
on the front of the interface unit.

SW1

SW2

SW3

When using C200H/HS, or C200HX/HG/HE, the words corresponding to the
channel numbers indicated below are occupied for each unit number set. Howev-
er, since the NT600S uses the allocated bits and words for processing, it does not
use these words.
These words are used as internal auxiliary relays.

Unit No.

Channel #

0

100 to 109

1

110 to 119

2

120 to 129

3

130 to 139

4

140 to 149

5

150 to 159

6

160 to 169

7

170 to 179

8 (*)

180 to 189

9 (*)

190 to 199

(*) Cannot be set with C



H.