2-3 grounding – Omron NT-series Programmable Terminal V022-E3-1 User Manual

Page 43

Advertising
background image

Caution

Note

Caution



%  

Section 2-2

Fit crimp-style terminals to the power cable. Connecting the wires of the cable to
the terminal block directly after merely twisting them together could cause fire and
other hazards.

Fork type

Round type

7 mm or less

7 mm or less

[Recommended terminals]

Maker

Type

(fork type)

Type

(round type)

Applicable Wire

(stranded wire)

Japan Solderless Terminal MFG

2-YS3A

2-3.5

Fuji Terminal

2-YAS3.5

V2-S3.5

1.04 to 2.63 mm

2

Nichifu Terminal

2Y-3.5

2-3.5

3-2-3

Grounding

The NT600S has a Grounding terminal

.

To prevent malfunctions due to excessive noise, and to prevent electric shock,
carry out class 3 grounding (grounding resistance of 100



or less) using a spe-

cial-purpose grounding cable (wire of at least 2 mm

2

).

Grounding wire length should be less than 20 m.

Note that if grounding wire is used in common with other equipment, or if it is con-
nected to a beam of a building, for example, the NT600S might be adversely af-
fected by this grounding.

Other
equipment

Other
equipment

Other
equipment

NT600S

NT600S

NT600S

Grounding common to several pieces of equipment:

Incorrect

Grounding for individual equipment:

Correct

Class 3 grounding
(grounding resistance
is 100

or less)

Carry out class 3 grounding (grounding wire must be less than 100



) before con-

necting the power supply. Otherwise there will be a danger of electric shock.