Reference

Reference

Reference



   

Section 6-4



The Set Flashing Display Command is cancelled by the End Flashing Display
Command or the Normal Display Command (refer to

7-4-2 Normal Display and

7-4-2 End Flashing Display).



The setting with this command remains valid until the screen display is switched
or another display attribute setting is made. The default display attributes are
set to a normal display when a screen is initially displayed.



Use this command with the Set Inverse Display Command (refer to

7-4-2 Set

Inverse Display) to produce a flashing inverse display.

Canceling the Flash Display

Use the following command to cancel the flash display mode.

End Flashing Display

Format

1B

[ESC]

25

%

Description

Clears the flashing display attribute so that all characters and marks sent subse-
quently are not flashing. Other attributes remain unchanged.



The flashing display attribute is set with the Set Flashing Display Command.



The setting with this command remains valid until the screen display is switched
or another display attribute setting is made. The default display attributes are
set to a normal display when a screen is initially displayed.

Specifying the Display Position

The display position of a character-string can be specified by the following com-
mand.

Set Cursor Position

Format

1B

[ESC]

2B

+

x

1

 

x

2

 

x

3

 

y

1

 

y

2

 

y

3

 

x

1

x

2

x

3

: X coordinate (3-digit BCD)

y

1

y

2

y

3

: Y coordinate (3-digit BCD)

Description

X coordinate

Y coordinate

000 to 639

000 to 399

Before displaying a character string with the Terminal commands, use this com-
mand to set the bottom-left point of the first character to be displayed.

The cursor position set with this command is also the bottom-left point of the first
character displayed if the displayed characters are enlarged.