Lamp and touch switch display status enquiry – Omron NT-series Programmable Terminal V022-E3-1 User Manual

Page 227

Advertising
background image

Reference



    &

Section 6-2

Bit ON:

The lamp or touch switch is turned on (or caused to flash).

Bit OFF: The lamp or touch switch is turned off.

Example

To turn on lamps and touch switches with the numbers 1, 5, 6, 7, and 26

m0

1

m0

2

m1

1

m1

2

m2

1

m2

2

m3

1

m3

2

m13

1

m13

2

=

E200000400000000000000000000

Description



Changes the display status of the lamps or touch switches.



Whether the lamp or touch switch which corresponds to the specified bit is
turned on or flashes is determined by the setting made using the support tool.

Lamp and Touch Switch Display (Number Specification)

Format

1B

[ESC]

n

1

 

n

2

 

m

1

 

51

Q

n

3

 

m

1

:

Display status

m

1

Display Status

0 (30

H

)

Not lit (normal display)

1 (31

H

)

Lit

2 (32

H

)

Flashing inverse

3 (33

H

)

All not lit

n

1

n

2

n

3

: Lamp or touch switch address (3-digit hexadecimal)

000 to 0FF

H

(0 to 255)

Description

Changes the lamp or touch switch lighting status.
Specify the display status as 3 (all not lit) to turn off all the lamps and touch
switches. In this case, specify the lamp or touch switch number to any number in
the permitted range.

The display attributes set with the Support Tool determine if lamps #0 to #111 light
continuously or flash. The display status set with this command is ignored.

Enquiry of the Display Status Use the following command to enquire whether a lamp or touch switch is displayed

continuously lit or flashing by specifying its number.

Lamp and Touch Switch Display Status Enquiry

Format

1B

[ESC]

n

1

 

n

2

 

52

R

n

3

 

n

1

n

2

n

3

: Lamp or touch switch address (3-digit hexadecimal)

000 to 0FF

H

(0 to 255)