Section 2-4

[Making the PC system settings]

The possible settings and existing settings which can be set by the PC system set-
ting are as given below.

Item

Possible Setting

Existing Setting

Baud rate

2400/4800/9600/19200 bps

9600 bps

Stop bit

1 or 2 stop bits

2 stop bits

Parity

Even/odd/non-parity

Even parity

Data length

ASCII 7 bits

ASCII 7 bits

Unit #

00 to 31

Unit #00



C-series C200HS, C200HX/HG/HE, CPM1, CQM1

Set the operating conditions to the PC system setting area when a C200HS or
CQM1 CPU is connected to the NT600S. The PC system setting area (data
memory) can be directly accessed from the peripheral tool (LSS etc.).

The following describes the switch settings so as to enable the PC system set-
tings. For the details of the operation with the PC system setting area, refer to the
“SYSMAC CQM1 Reference Manual” (W228-E1-



).

[Switch settings] (C200HS, C200HX/HG/HE, CQM1)



RS-232C port communication
condition settings
Set DIP switch 5 to OFF (right side)
to enable the PC system settings.

CPU unit DIP switch settings

[Switch settings] (CPM1)



Set the mode setting switch to
the “HOST” (upper) position.

CPM1

CPM1
-CIF01

[PC system setting area settings]

Write settings to the PC system setting area (data memory) according to the port
used to connect to the NT600S.

Channel #

Writing Value

Settings

DM6645

0001

Host link mode and conditions are set.

DM6646

0303

Data length: 7 bits, 2 stop bits, even parity,
baud rate: 9600 bps

DM6646

0304

Data length: 7 bits, 2 stop bits, even parity,
baud rate: 19200 bps

DM6648

0000

Unit No. 0