802BT/802R Video Test Generator User Guide

119

4. Using the

Format

knob, select the signal format you want to use.

Any built-in formats may be used for this test. However, we recommend using several

formats spread over a wide range of frequencies. For example, the Test165 format is

commonly used to test at the maximum pixel frequency (165 MHz), while the DMT0660

format can be used to test at a very low frequency (25.175 MHz).Use the following

formats to test single-link DVI over a range of frequencies:

5. Start the analyzer (see

Starting the analyzer

” on page 113).

Format

Pixel rate (Mhz)

TEST165

165.000

DMT1660

162.000

DMT1285G

157.500

DMT1285A

148.500

DMT1648

135.000

DMT1275A

129.600

DMT1185

121.500

DMT1260G

108.000

DMT1085

94.500

DMT1170

94.200

DMT1075

78.750

DMT1070

75.000

720p60

74.250

DMT1060

65.000

DMT0885

56.250

DMT0872

50.000

DMT0875

49.500

DMT1043

44.900

DMT0860

40.000

DMT0685

36.000

DMT0785H

35.500

DMT0675

31.500

SMT0760V

28.322

DMT0660

25.175