453

NLNK

Number of digital LiNKs

Class

Format parameter setting - Digital video signal

Description

Determines the number of links used by the LVDI digital outputs on generators that

support LVDI outputs. The NLNK? query returns the current setting of NLNK.

Command syntax

NLNK links

links integer

0 = Default, let the generator decide

1 = Single link

2 = Dual link

Query syntax

NLNK?

Query response

links

Other required

commands

The

FMTU

command instructs the generator to use the new setting. The

ALLU

command

updates hardware to the new setting and redraws the test image.

Example

NLNK 2; FMTU