Quantum Data 802BT User Manual

Page 98

Advertising
background image

88

Chapter 6

Working with Test Sequences

IMGL

SMPTEbar // loads an image

STEP

2

// selects a step to be edited

SDLY

5.0

// sets the delay for the current step to five seconds

FMTL

720p60

// loads a second format (same image)

IMGL

Outline1 // loads an image

STEP

3

// selects a step to be edited

SDLY

5.0

// sets the delay for the current step to five seconds

FMTL

1080i29 // loads a third format

IMGL

Geom_4 // loads another image

SEQE

// ends the sequence editing session

SEQA

MySeq

// saves the current contents of the sequence editor

2. Save the text file, using a *.txt extension.

3. Establish a terminal session with the generator.

4. Transfer the text file to the generator. For example, to transfer the file using

HyperTerminal, do the following:

a.

On the

Transfer

menu, click

Send Text File

. The

Send Text File

dialog box

appears.

b.

Select the text file you want to send, and then click

Open

. HyperTerminal displays

the commands as they are sent.

c.

Press

Enter

once to ensure that the last command is sent.

To insert a sequence at a specific location in the sequence list:

1. Establish a terminal session with the generator.

2. Enter the following commands:

DIRL

seq

// loads sequence directory into edit buffer

DIRB

// begins a directory editing session

NAMI

1 MySeq

// assigns sequence to sequence list at 1

DIRE

// ends the directory editing session

DIRS

// saves contents of directory as current name

Creating and editing test sequences using the internal editor

You can use the generator’s internal Sequence Editor to create, edit and run test

sequences without using VGM. The 802 can be configured to allow an operator to run only

certain sequence files in the sequence mode. The 802 maintains a list of these accessible

sequences in non-volatile memory. You will need to edit the list if you wish to add

sequences you have created. The procedures for creating and editing the sequence file

list are provided below.

To create a test sequence using the internal sequence editor:

1. Turn on the generator while pressing the Image key until

programmer

is displayed.

2. Select the SeqList image.

Advertising
This manual is related to the following products: