Video Test Generator User Guide

537

Other required

commands

The desired sync type selected must not be set to void with the

ASCT

,

DSCT

, or

DSST

commands. To actually output the selected sync signal, it must be gated on with the

appropriate

ASSG

,

ASBG

,

ASGG

,

ASRG

,

CSPG

,

HSPG

, and

VSPG

settings.

Example

DSST 1 // Set Amer. H&V in buffer
HSPG 1 // Enable H sync in buffer
VSPG 1 // Enable V sync in buffer
SSST 1 // Select sep H&V sync in buffer