Quantum Data 802BT User Manual

Page 179

Advertising
background image

802BT/802R Video Test Generator User Guide

169

4. Using the

Image

knob, select the ON setting to enable analyzer images.

5. Using the

Format

knob, select the

Auto Based On

field.

6. Using the

Image

knob, select CURRENT in the highlighted field to measure the

HDMI/DVI signal originating

internally

from the generator.

7. Press and release the

Step

key to save the currently displayed parameters.

The light on the

Step

key extinguishes, and the new settings are implemented for

analyzer mode operation.

To configure the analyzer to emulate the EDID structure of a display:

1. Determine the HDMI/DVI display you wish to emulate and if possible obtain a text file

of its EDID.

Note: This can be obtained from the manufacturer or by reading the EDID using the

HDMI/DVI generator. For procedures on reading the EDID of a display with the

generator, please refer to

Viewing EDID from a display

” on page 171.

2. Connect an HDMI/DVI cable between the HDMI/DVI Tx and Rx connectors on the

generator.

3. Using a terminal emulator, establish a terminal session with the generator (see page

14).

4. Modify the EDID structure in the generator using the

XDID

and

DIDU

commands.

For example, to change the color characteristics of the EDID structure (a total of 10

bytes starting at byte 19), you could use the following command strings:

XDID 19 A E88A82A0564796240F48
DIDU

To program multiple segments (or the entire EDID structure) at once, create a text file

containing the EDID. Then send the text file to the generator using your terminal

emulator’s file transfer feature.

The following commands write the entire EDID block 0:

XDID 0 80 00FFFFFFFFFFFF005A63118F01010101130D010380221B782A4706A55C47
9C251E4F54BFEF008180310A010101010101010101010101302A009851002A40307013
00520E1100001E000000FF004132333033313931353335390A000000FD00324B1E530E
000A202020202020000000FC0056583730302D330A20202020200095
DIDU

5. To verify the EDID structure, use the

EDID?

query. This command will display the entire

EDID structure in ASCII hex format.

To view a specific segment of EDID, use the

I2CR?

query. This command will display

the requested EDID in ASCII hex format.