Video Test Generator User Guide

357

GPIB

GPIB address

Class

GPIB port control

Description

Sets the address of the generator on the GPIB port. The address change takes affect as

soon as the command is issued. The new address setting will be maintained until 1) the

address is changed another GPIB command, 2) the unit is re-initialized with an

INIT

command or 3) the unit is re-initialized because the power-up self-test found corrupted

data in battery backed system memory. In cases 2 and 3, the GPIB address will revert to

the address set on the GPIB address switches, if the unit has them. The address reverts to

15 if the unit does not have GPIB address switches. The GPIB? query returns the current

GPIB address of the unit.

Command syntax

GPIB address

address

integer, 0-30

Query syntax

GPIB?

Query response

address

Example

GPIB 5 // Set GPIB address to 5