Video Test Generator User Guide

415

LSPG

Line Sync Pulse Gate

Class

Format parameter settings

Description

Enables and disables the digital horizontal sync output. The LSPG? query returns the

current LSPG mode.

Command syntax

LSPG mode

mode integer

0 = OFF

1 = ON

Query syntax

LSPG?

Query response

0 or 1

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Example

LSPG 1

// Enable Line Sync

FMTU

// Update hardware to new settings