Strg, Strg stretching scl low signal – Quantum Data 802BT User Manual

Page 548

Advertising
background image

538

Appendix A Command Reference

STRG

STRetchinG SCL Low Signal

Class

EDID and DDC control

Description

Enables a stretching capability for the receiver of the HDMI analyzer. Each time a host

accesses the I2C receiver bus (for example, to read the EDID), the receiver stretches the

SCL low signal for 5 ms.

Enable stretching for testing purposes only.

Command syntax

STRG value

value

0 = deactivate stretching

1 = activate stretching of SCL low signal for 5 ms

Query syntax

STRG?

Query response

0 or 1

Example

STRG 1
DIDU

Related commands

DIDU