ASSS

Analog Sync Signal Swing

Class

Format parameter setting - Analog video signal

Description

Sets the maximum peak-to-peak swing for any composite sync that is added to any of the

three analog video channels. The actual peak-to-peak swing of the analog sync signals at

the output connectors equals the product of ASSS multiplied by ASSC. The ASSS? query

returns the current setting of ASSS.

Command syntax

ASSS level

level

min = 0.000 volts (floating point accepted)

max = 0.400 volts (floating point accepted)

Query syntax

ASSS?

Query response

level

Other required

commands

One or more

ASSG

modes must be set to ON and the

SSST

type must be 4, 5, 6 or 7 to

output analog sync. The

FMTU

command instructs the generator to use the new setting.

The

ALLU

command updates hardware to the new setting and redraws the test image.

Example

ASSS 0.286 // Set sync swing to 286 mV in buffer
FMTU

// Update hardware to current buffer contents