562

Appendix A Command Reference

VRES

Vertical RESolution

Class

Format parameter setting - Video resolution

Description

Establishes the number of active lines per frame. The VRES? query returns the current

setting of VRES.

Command syntax

VRES lines

lines

min =

1 (when SCAN = 1) or

2 (when SCAN = 2)

max = the lesser of

VTOT-1 (when SCAN = 1) or

VTOT-3 (when SCAN = 2)

Must be an even number when SCAN = 2.

Query syntax

VRES?

Query response

lines

Other required

commands

The

ALLU

command updates hardware to the new setting and redraws the test image.

Example

VRES 480 // Set 480 active lines in buffer
ALLU

// Configure hardware and redraw image