Hspd, Hspd horizontal sync pulse delay – Quantum Data 802BT User Manual

Page 380

Advertising
background image

370

Appendix A Command Reference

HSPD

Horizontal Sync Pulse Delay

Class

Format parameter setting - Synchronization

Description

Establishes the delay between the leading edge of blanking and the leading edge of the

horizontal sync pulse. The HSPD? query returns the current setting of HSPD.

Command syntax

HSPD pixels

pixels

min = 1

max = HTOT - HRES - HSPW

Query syntax

HSPD?

Query response

pixels

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Example

HSPD 16 // Set 16 pixel pulse delay in buffer
FMTU

// Update hardware to current buffer contents

Advertising
This manual is related to the following products: