Equa – Quantum Data 802BT User Manual

Page 321

Advertising
background image

Video Test Generator User Guide

311

EQUA

EQUalization interval After vertical sync pulse

Class

Format parameter setting - synchronization

Description

Establishes the width of the equalization interval after the vertical sync pulse in each field

whenever a serrated and equalized sync type is selected via either

ASCT

or

DSCT

commands and selected via the

SSST

command. If the type specified for the selected

sync signal is one of the CCIR types, then the actual equalization interval output by the

generator will be 0.5 lines shorter than the whole number specified. The EQUA? query

returns the current setting of EQUA.

Command syntax

EQUA lines

lines

min = 0

max = number of lines after vertical sync before video

Query syntax

EQUA?

Query response

lines

Other required

commands

The

FMTU

command instructs the generator to use the new setting. The

ALLU

command

updates hardware to the new setting and redraws the test image.

Example

EQUA 3 // Set post-equalization to 3 lines in buffer
FMTU

// Update hardware to current buffer contents