USIZ

Unit of measure used for physical SIZes

Class

System control

Description

Sets the units of measure assumed by

HSIZ

and

VSIZ

commands to establish the

physical size of the image that appears on the CRT (context sensitive; see

FMTB

and

FMTE

). The USIZ? query returns the current setting of USIZ.

Note: Changing the USIZ parameter between inches and millimeters will convert the

current HSIZ and VSIZ values to match the new unit of measure. For example, if USIZ is in

inches and the current HSIZ is 10 (inches), changing USIZ from inches to mm will change

HSIZ to 25.4 (mm). The USIZ command should be sent before specifying physical sizes in

format command files.

Command syntax

USIZ units

units

0 = sizes not given (use default)

1 = inches

2 = mm

Query syntax

USIZ?

Query response

units

Other required

commands

The

ALLU

command updates hardware to the new setting and redraws the test image,

taking the new units into account.

Example

FMTB

// Begin editing session

// One or more format editing commands ...

USIZ 1

// Select inches as unit of measure in buffer

HSIZ 10.4 // Set width to 10.4 in buffer
VSIZ 7.8

// Set height to 7.8 in buffer

ALLU

// Test the new settings

// One or more format editing commands ...

FMTE

// End editing session