802BT/802R Video Test Generator User Guide

125

Measuring pixel errors in patch

The analyzer can test and analyze the transmission quality of an external HDMI/DVI

transmit device using a delta error patch pattern. The analyzer captures all or a portion of

an external image (patch pattern) and verifies that all pixels match over a number of

frames. The results are output to an HDMI/DVI display using a special image.

To test an external HDMI/DVI signal using delta error patch pattern:

1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator.

2. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator.

3. If necessary, set the proper HDMI/DVI signal source and delta error patch parameters

within the generator.

See

Starting the Analyzer Setup Utility

” on page 112 for steps on viewing the

current analyzer configuration.

To edit HDMI/DVI signal source parameters, see “

Setting up analyzer to measure

timing

” on page 114.

To edit delta error patch parameters, see “

Setting delta error patch parameters

” on

page 123.

4. (HDMI only) If desired, monitor the video signal received on the HDMI Rx connector

(see

Monitoring HDMI analyzer signal input

” on page 110).

5. Generate a static image from the HDMI/DVI transmit device.

6. Using the

Format

knob, select an appropriate format for the connected HDMI/DVI

display.

Note: To automatically configure the Format knob list based on the EDID structure of

a DDC-compliant display, hold down the R key, then press and release the ACS key.