Cspp, Cspp composite sync pulse polarity – Quantum Data 802BT User Manual

Page 270

Advertising
background image

260

Appendix A Command Reference

CSPP

Composite Sync Pulse Polarity

Class

Format parameter setting - Synchronization

Description

Establishes the logic sense of the digital composite sync output. The CSPP? query returns

the current setting of CSPP.

Command syntax

CSPP polarity

polarity

0 = active-low (negative going pulse)

1 = active-high (positive going pulse)

Query syntax

CSPP?

Query response

0 or 1

Other required

commands

In order to use digital composite sync, it must be gated on with the

CSPG

command and

selected with the

SSST

command. The

FMTU

command instructs the generator to use the

new setting. The

ALLU

command updates hardware to the new setting and redraws the

test image.

Example

CSPG 1 // Enable dig comp sync in buffer
CSPP 1 // Select active hi in buffer
SSST 2 // Choose digital comp sync type in buffer
FMTU

// Update hardware to current buffer contents