Hres, Hres horizontal resolution – Quantum Data 802BT User Manual

Page 378

Advertising
background image

368

Appendix A Command Reference

HRES

Horizontal RESolution

Class

Format parameter setting - Video resolution

Description

Establishes the number of active pixels per line. The HRES? query returns the current

setting of HRES.

Command syntax

HRES pixels

pixels

min = 16

max depends on VRES and model of generator

Query syntax

HRES?

Query response

pixels

Other required

commands

The

ALLU

command updates hardware to the new setting and redraws the test image.

Example

HRES 480 // Set 480 active pixels line in buffer