372

Appendix A Command Reference

HSPP

Horizontal Sync Pulse Polarity

Class

Format parameter setting - Synchronization

Description

Establishes the logic sense of the digital horizontal sync outputs. Setting polarity to 1

causes the leading edge of horizontal sync to be a low-to-high transition. Setting polarity to

0 causes the leading edge of horizontal sync to be a high-to-low transition. The HSPP?

query returns the current polarity of HSPP.

Command syntax

HSPP polarity

polarity

0 = active-low (negative going pulse)

1 = active-high (positive going pulse)

Query syntax

HSPP?

Query response

0 or 1

Other required

commands

To use digital horizontal sync, it must be gated on with the

HSPG

command and digital

separate H and V sync must be selected with the

SSST

command. The

FMTU

command

instructs the generator to use the new settings. The

ALLU

command updates the

hardware to the new settings and redraws the test image.

Example

HSPP 0 // Set active low H sync in buffer
HSPG 1 // Enable H sync output in buffer
SSST 1 // Select H&V sync type in buffer
FMTU

// Update hardware to current buffer contents

Advertising