Appendix C

Error Messages

2400

Analog composite sync type and digital separate sync type incompatible

The generator hardware configuration does not support analog composite sync and digital

separate sync being active at he same time for the given analog composite sync type

parameter value (ASCT setting) and digital separate sync type parameter value (DSST

setting).

2401

Invalid horizontal sync pulse delay

The generator hardware configuration does not support the format’s current horizontal

sync pulse delay setting

2405

Frame sync pulse delay negative

The video format’s frame sync pulse delay setting must be zero or a positive number.

2406

Frame sync pulse delay too large

The video format’s frame sync pulse delay setting exceeds the maximum limit supported

by the generator hardware configuration.

2407

Negative probe sync pulse vertical delay

The video format’s probe pulse vertical delay setting must be zero or a positive number.

2408

Probe sync pulse vertical delay too large

The video format’s probe pulse vertical delay setting exceeds the maximum limit

supported by the generator hardware configuration.

2409

Negative probe sync pulse horizontal delay

The video format’s probe pulse horizontal delay setting must be zero or a positive number.

2410

Probe sync pulse horizontal delay too large

The video format’s probe pulse horizontal delay setting exceeds the maximum limit

supported by the generator hardware configuration.

2425

Sync type selection not supported

The current firmware does not support the video format’s active sync type selection (SSST

setting) or the active sync type selection is not supported by the current analog video type

selection (AVST setting).

2430

Vertical pulse delay extends sync beyond blanking

The generator hardware configuration does not support non-interlaced video formats

having a vertical sync pulse period greater that the vertical blanking period

2450

Vertical pulse delay extends sync beyond blanking

The generator hardware configuration does not support interlaced video formats having a

vertical sync pulse period greater that the individual blanking periods between the fields.