Avss, Avss analog video signal swing – Quantum Data 802BT User Manual

Page 253

Advertising
background image

Video Test Generator User Guide

243

AVSS

Analog Video Signal Swing

Class

Format parameter setting - Analog video signal

Description

Sets the maximum peak-to-peak swing for all three analog video channels. The actual

peak-to-peak swing of the analog video signals at the output connectors equals the

product of AVSS multiplied by AVSC. The AVSS? query returns the current setting of

AVSS.

Command syntax

AVSS level

level

0.000 to 1.000 volts (floating point accepted)

Query syntax

AVSS?

Query response

level

Other required

commands

Analog video must be enabled with the

AVST

command in order to output an analog video

signal. The

FMTU

command instructs the generator to use the new setting. The

ALLU

command updates hardware to the new setting and redraws the test image.

Example 1

This example uses the AVSS command changes the output level of the NTSC format from

714mV to 500mV, and adds the revised format to the format knob list.

FMTL NTSC
FMTB
AVSS 0.5
FMTE
FMTA NTSC_1

DIRL fmt
DIRB
NAMI 1 NTSC_01
DIRE
DIRS

Example 2

This example enables analog video, and sets the video swing.

AVST 2

// Select RGB component color video in buffer

AVSS 0.714

// Set to 714 mV in buffer

FMTU

// Update hardware to current buffer contents

Advertising
This manual is related to the following products: