Video Test Generator User Guide

247

BASE

number BASE

Class

Direct processor control

Description

Establishes the radix of address and data parameters passed to or returned from the

ADDR, GETA, GETR, PUTA, PUTR, and CALL commands. If a negative radix is specified,

then parameters passed to (or returned from) these functions are assumed to be signed.

For example, if BASE= -16, then the value -1 communicates the value FFFFFFFF hex.

The BASE? query returns the current setting of BASE. The radix radix always is passed

and returned in base 10, regardless of the setting of BASE. BASE is preset to -10 each

time the generator is powered on. Base -10 is the preferred radix. The BASE? query

returns the current setting of BASE.

Note: This command is used only with custom applications and command files created by

Quantum Data.

Command syntax

BASE radix

radix

-36 to -2 or 2 to 36

Query syntax

BASE?

Query response