Fspw, Fspw frame sync pulse width – Quantum Data 802BT User Manual

Page 355

Advertising
background image

Video Test Generator User Guide

345

FSPW

Frame Sync Pulse Width

Class

Format parameter setting - Synchronization

Description

Establishes the width of the frame sync pulse. The FSPW? query returns the current

setting of FSPW.

Command syntax

FSPW pixels

pixels

min = 1

max = HTOT - 1

Query syntax

FSPW?

Query response

pixels

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Example

FSPG 1

// Enable Frame Sync

FSPP 1

// Set for positive going pulse

FSPW 20

// Make the pulse 20 pixels wide

FSPG 300 // Pulse to occur 300 lines after the last line of active video
FMTU

// Update hardware to new settings

Advertising