Installation procedures, Step 2 - mounting the aquavar controller, Warning – Xylem IM043 AQUAVAR Variable Speed Pump Control User Manual

Page 11

Advertising
background image

10

Step 2 - Mounting the AQUAVAR controller:

1. The AQUAVAR controller drive head

is supplied with all mounting

hardware.

2. Remove the 3 screws from the

AQUAVAR cover.

3. Place the center bit in the

AQUAVAR heat sink.

4. Place the AQUAVAR on the motor.

5. Hang the 4 clamps by the heat

sink and mount with the 4 screws.

6. Mount the cover with the 3 screws

(remember to use the gaskets).

7. Depending on pump orientation,

the display can be rotated 180º.

Installation Procedures

Gasket

4 screws

M5x50

Transducer

Display

changeable

to 180º

Connection

motor

conduit box

Thermistor

4 mounting

clamps

Diagram 4

THE AQUAVAR CONTROLLER DRIvE HEAD AND PuMP MuST BE TOTALLY DISCONNECTED

FROM ALL POWER SuPPLY SOuRCES BEFORE BEgINNINg INSTALLATION OR REPAIR.

WARNINg

FAILuRE TO DISCONNECT ELECTRICAL POWER BEFORE ATTEMPTINg ANY MAINTE-

NANCE CAN CAuSE SHOCk, BuRNS, OR DEATH.

WARNINg!

WARNING

hazardous voltage

can shock, burn or

cause death.

Advertising