Pressure transducer data, Appendix a, Specifications – Xylem IM043 AQUAVAR Variable Speed Pump Control User Manual

Page 74

Advertising
background image

73

Model Delta 692

Differential Pressure

Transducer and Orifice Plate

Appendix A

3

4

5

2

1

P1

P2

Diagram 22

Specifications

Standard 80096 ND

Range (FS)”

2, 5 bar - 37 PSI

Over Pressure (PMAX)

12 bar - 177 PSI

Signal over Range

4... 20mA; 2 wire

Power Supply

9... 33 volts DC

E1 Connection

DIN-plug 43650

OUT

IN +

supply

2-wire

2

1

3

Diagram 23

Hydraulic connection

R

1

/

8

"

Linearity

tip± .25%FS; max.±.5%FS

Stability

tip± .1%FS; max.±.5%FS

Operating

Temperature

-15° - 80° C

Storage

Temperature

-15° - 80° C

Materials

Stainless steel (body)

Ceramic (diaphragm)

Diagram 24

Nominal Pipe/

Constant

Discharge Size

Flow Range

1"

12-35 GPM

1"

18-52 GPM

1½"

20-62 GPM

1½"

32-90 GPM

2½"

35-105 GPM

2½"

52-160 GPM

3"

52-160 GPM

3"

70-210 GPM

3"

120-350 GPM

1 P1 Pressure high (+)
2 P2 Pressure low (-)
3 gaskets
4 ceramic component
5 vent plug

Pressure Transducer Data