Appendix b – Xylem IM043 AQUAVAR Variable Speed Pump Control User Manual

Page 75

Advertising
background image

AQUAVAR Controller Drive Head Technical Data and Terminals

Instructions: Use this supplement for installation and wiring of AQUAVAR models 04168321, 04168331,

04168371, 04168491, 04168501 and 04168511.

AQUAVAR Controller Technical Data:

AQUAVAR Controller

Motor

Supply Voltage

Recommended

Type

Rated Output Voltage

Current

40-60 Hz

Circuit Protection *

04168321

2 HP

3 ph 230V

7 A

Single Phase

15 Amps

240 VAC ± 10%

04168331

3 HP

3 ph 230V

10 A

Single Phase

15 Amps

240 VAC ± 10%

04168371

5 HP

3 ph 460V

9 A

Three Phase

15 Amps

380-460 VAC ± 15%

04168491

7½ HP

3 ph 460V

13½

A

Three Phase

20 Amps

380-460 VAC ± 15%

04168501

10 HP

3 ph 460V

17 A

Three Phase

25 Amps

380-460 VAC ± 15%

04168511

15 HP

3 ph 460V

23 A

Three Phase

35 Amps

380-460 VAC ± 15%

*Note: Recommend using delay type fused protection. Always refer to NEC and local codes.

Maximum current:

There is a dynamic limit of 500 pulses for current which exceeds maximum allowable. If current

remains above the maximum after 500 pulses, the AQUAVAR controller will shut down. After

correct ing the current problem, the unit may be reset by disconnecting the power supply for over

30 seconds.
Output voltage:

Single phase units:

three phase 230 VAC

Three phase units:

three phase 460 VAC

Output frequency: Operator selectable up to 60 hz

Min. = 0; Max. = 60 hz

Electrical Efficiency > 95%
Protection Against: Short circuit, ground fault, under-voltage, electronics overheating/overload,

overvoltage, motor over temperature, standard electronic low/no water (or

with external switch), radio emission per EMV, ENV, and FCC

Ambient Temp.: 5° - 40° C; (41° - 105° F) - Consult factory for maximum applications with

temperatures greater than 105

° F.

Storage Temp.: -25° - 55° C
Humidity:

90° F at 105° F, non-condensing. Condensation not allowed.

Appendix B

74

Minimum temperature can be increased to 125°F by using a higher power rating AQUAVAR controller.

Note

Advertising