4 sio converter (option) – IAI America ACON-SE User Manual

Page 31

Advertising
background image

21

6SHFL¿FDWLRQV

2.4 SIO

Converter

(Option)

Model: RCB-TU-SIO-A (vertical installation)

RCB-TU-SIO-B (horizontal installation)

This unit is a RS232C-RS485 converter.
If multiple controllers are linked, you can connect a teaching pendant to the mini DIN, 8-pin connector to move, or
edit parameters, for all axes.

Ɣ Description

of

Functions

[1] Power/emergency stop terminal block (TB2)

EMG1, EMG2 Provide a contact output for the emergency-stop switch on the teaching pendant

(RCM-T/E). EMG1 and EMG2 connect to the emergency-stop switch on the teaching
pendant when the PORT switch is ON, or are shorted when the PORT switch is OFF.
These terminals comprise an interlock with a safety circuit provided by the user.

24V

Positive side of the 24V power supply (power supply for the teaching pendant and
conversion circuit, power consumption: 0.1A or less)

0V

Negative side of the 24V power supply

FG

FG of the 24V power supply

[2] Link-connection terminal block (TB1)

A connection port for linking the controller.
³$´RQWKHOHIWVLGHFRQQHFWVWR6*$ OLQHFRORURUDQJHUHG RIWKHUHOD\FDEOH
³%´RQWKHULJKWVLGHFRQQHFWVWR6*% OLQHFRlor: orange/black 1) of the relay cable.
(Note) Be sure to use twisted pair wires for the above two connections (SGA/SGB).

[3] Link-connection connector (J4, J5)

An e-con connection port for linking the controller. The optional link cable (CB-RCB-CTL002) can be
connected to this port directly. However, J4 and J5 allow only two-axis connection. When connecting three or
more axes, use the terminal block of [2].

[1] Power/emergency stop terminal block (TB2)

[2] Link-connection terminal block (TB1)

[3] Link-connection connector (J4, J5)

[7] Monitor LEDs

[4] D-sub, 9-pin connector

[6] PORT switch

[5] Mini DIN, 8-pin connector

Advertising