3. Installation and W

iring

PC (USB port)

Conversion unit

(RCB-CV-USB)

SIO isolator

RS485

communication

Insulation

The isolator
communication cable
CB-RCB-SIO must be
purchased
separately.

Controller

24-V power

supply

Cable supplied with PC software (RCM-101-USB)

(USB cable + RCB-CV-USB + CB-RCA-SIO)

Connecting the PC to the ACON without using SIO converter (Grounding the positive side)

Be sure to connect the PC using a SIO isolator (RCB-ISL-SIO).
Take note, however, that only the RCM-101-USB PC software supports this configuration and RCM-101-MW