3. Installation and W

iring

3.8.2

Cutting off the Motor Drive Power Supply

If the safety category of the entire equipment requires motor drive power cut off, connect the EMG relay contact
between the MPI terminal and MPO terminal.
In addition, connect 24V of the controller power supply to the EMG terminal.

(Note) Please pay sufficient attention that the EMG switch of the teaching pendant leads to motor drive

signal shutdown and not motor drive power cutoff.

(1)

When the SIO converter is used

Teaching pendant

EMG push

button

T.P. connector

SIO converter

ACON-SE controller

EMG reset

switch

EMG

push

button

Terminal

block

Input power supply

24 VDC

SIO

communication

SIO connector

SIO

connector

connection

detecting

circuit

Connection

detecting

signal (H)

Drive stop
signal (L)

Ti

m

e

const

ant

Control
power
supply

Power supply terminal block

Power supply terminal block (Unit 2)

EMG signal

detection

(H)

Motor drive
power
supply

Motor

drive

circuit

Power supply terminal block (Unit 3)