IAI America ACON-SE User Manual

Page 45

Advertising
background image

35

3. Installation and W

iring

(2)

Connecting the multiple axes

Item

Description

Maximum number of units that can
be connected

16 axes max. (depending on the operation mode)

Communication cable length

Total cable length: 100 m or less

SIO communication main line

Twisted-pair shielded cable (AWG22)
Recommended brand: Taiyo Electric Wire & Cable HK-SB/20276 x
L, 2P x AWG22

Terminal resistor

220

:, 1/4 W

Teaching pendant

PC, PLC

* The SIO communication main line must be prepared by the customer.

Each one unit of the junction, E-Con connector and terminal resistor are supplied with the controller link
cable.

Caution: [1]

If normal communication cannot be performed with a communication error occurring when the
total communication cable length is 10 m or more, connect the terminal resistor to the last
axis.

[2]

For the power supplies of the SIO converter and all controllers, make 0V in common.

[3]

Connect a shielded cable to FG on an axis basis.

[4]

If the total link cable length is more than 30 m, use the wire size of 22AWG or larger.

[5]

If the positive side of the 24-V power supply is grounded, do not connect the SIO converter
and the FG terminal of the PC to ground.
If the positive side of the 24-V power supply is grounded and no SIO converter is used, be
sure to use a SIO isolator (RCB-ISL-SIO). (Refer to the next page.)

Controller 1

E-Con connector (AMP 4-1473562-4: housing color green)

E-Con connector (AMP 3-1473562-4: housing color orange)

Junction (AMP 5-1473574-4)

Recommended: HK-SB/20276 x L, 2P x AWG22

SIO converter

SIO communication main line*

Terminal resistor

Controller link cable

Controller 2

Controller n