5. Parameter Settings
Point No. 1
Point No. 2
Point No. 3
Point No. 3
Point No. 2
Point No. 4
Point No. 4
Point No. 1
Point No. 1
Point No. 2
Point No. 3
Point No. 3
Point No. 2
Point No. 4
Point No. 4
Point No. 1
If the actuator is moved in the order to positions 1
o 2 o 3 o 4, the actuator will operate differently depending on
whether or not shortcut is selected.
When shortcut is not selected
When shortcut is selected
Ɣ
Absolute unit (No. 83 ETYP)
Parameter No. 83 sets whether or not an optional simple absolute unit is used.
Setting
Not used
0
Used
1
Ɣ
Current-limiting value at stopping due to missed push-motion (No. 91 PSFC)
The current-limiting value at stopping when the actuator misses the push-motion is defined.
Parameter
No. 91
Description
0
Current-limiting value during movement
(2.8 to 4 times depending on the characteristics of the actuator)
1
Current-limiting value during push & hold operation