86

5. Parameter Settings

Point No. 1

Point No. 2

Point No. 3

Point No. 3

Point No. 2

Point No. 4

Point No. 4

Point No. 1

Point No. 1

Point No. 2

Point No. 3

Point No. 3

Point No. 2

Point No. 4

Point No. 4

Point No. 1

If the actuator is moved in the order to positions 1

o 2 o 3 o 4, the actuator will operate differently depending on

whether or not shortcut is selected.

When shortcut is not selected

When shortcut is selected

Ɣ

Absolute unit (No. 83 ETYP)

Parameter No. 83 sets whether or not an optional simple absolute unit is used.

Setting

Not used

0

Used

1

Ɣ

Current-limiting value at stopping due to missed push-motion (No. 91 PSFC)

The current-limiting value at stopping when the actuator misses the push-motion is defined.

Parameter

No. 91

Description

0

Current-limiting value during movement

(2.8 to 4 times depending on the characteristics of the actuator)

1

Current-limiting value during push & hold operation