4. Description of Operating Functions

[Push & hold operation]
It defines the maximum push amount from the target position in the push & hold
operation.
Set the positioning band in such a way as to prevent positioning completion before the
actuator contacts work by considering mechanical variations of work.

(8) Zone

+/-:

y

It defines the zone where the zone output signal turns ON.

It can be set separately for each target position.

[Setting example]

No.

Position

[mm]

Zone +

[mm]

=RQH±

[mm]

Comment

0

5.00 100.00

0.00

1

380.00 400.00 300.00

2

200.00 250.00 150.00

Movement command to position No. 0

Movement command to position No. 1

* The functions have been changed in the new version. Refer to the notes

provided at the beginning of the manual.

Position at which the position complete signal turns ON when
the actuator contacts work and push completion is judged

Speed

Push

speed

Target position

Positioning band (maximum push amount)

Zone output signal

Home

Target
position

+ side limit

Zone output signal

+ side limit

 side limit

Target
position