44
4. Description of Operating Functions
[Push & hold operation]
It defines the maximum push amount from the target position in the push & hold
operation.
Set the positioning band in such a way as to prevent positioning completion before the
actuator contacts work by considering mechanical variations of work.
(8) Zone
+/-:
y
It defines the zone where the zone output signal turns ON.
It can be set separately for each target position.
[Setting example]
No.
Position
[mm]
Zone +
[mm]
=RQH±
[mm]
Comment
0
5.00 100.00
0.00
1
380.00 400.00 300.00
2
200.00 250.00 150.00
Movement command to position No. 0
Movement command to position No. 1
* The functions have been changed in the new version. Refer to the notes
provided at the beginning of the manual.
Position at which the position complete signal turns ON when
the actuator contacts work and push completion is judged
Speed
Push
speed
Target position
Positioning band (maximum push amount)
Zone output signal
Home
Target
position
+ side limit
Zone output signal
+ side limit
side limit
Target