IAI America ACON-SE User Manual

Page 81

Advertising
background image

71

4. Description of Operating Functions

4.4.9

Pitch Feeding by Relative Coordinate Specification

For the target position in the position table, relative coordinate specification is also available. Therefore, it can be
used in constant-pitch positioning (constant-pitch feeding).

(1) Operation example in the position no.

The following is the description of an example of positioning with a

50 mm pitch from position No. 1. Create a position table as shown below. Operational completion is judged
E\3/&¶VH[HFXWLQJFRXQWFRQWURO7KHFRPELQHG use of the zone signal allows a double check.

Example of position table

No.

Position

[mm]

Zone +

[mm]

=RQH±

[mm]

Incremental Comment

0 *

*

*

0

1 100.00

300.50

99.50

0

2 50.00 300.50

99.50

1

*Indicates the relative coordinate specification with the teaching pendant (RCM-T).

Position 1

50 mm pitch

Forward end
direction

Last work

Zone output signal

Set the coordinate value for the next last work to the positive-side boundary value.

=

*Indicates the relative coordinate specification with the teaching pendant (CON-T).

(I: Relative coordinate specification, A: Absolute coordinate specification)

Advertising