First-order lag filter

More gradual acceleration/deceleration curves are drawn than the linear
acceleration/deceleration (trapezoid pattern).
Use this in the applications by giving micro vibrations to work during
acceleration/deceleration not desired.

* Set the degree of primary delay using parameter No. 55 [Primary filter time constant for

position command]. The setting unit is msec, and a desired value can be set in
0.1-msec increments in a range of 0.0 to 100.0.
,I³´LVVHWWKHSULPDU\GHOay filter becomes invalid.
Take note, however, that this setting will not be reflected in jogging/inching by PC or