14 get output rate, 15 get sensor thickness, 16 get output thickness – INFICON SQC-310 Thin Film Deposition Controller User Manual

Page 95: 17 get sensor frequency/crystal life

Advertising
background image

5 - 15

IP

N 07

4-

55

0-

P1

B

SQC-310 Operating Manual

5.3.14 Get Output Rate

Command: . . . . . M

Description: . . . . Returns the average rate of all sensors assigned to the

requested output.

Parameters: . . . . Output Number

Example: . . . . . . To Get Output 1 rate, send: M1

The return string is of the form: 1.00

5.3.15 Get Sensor Thickness

Command: . . . . . N

Description: . . . . Returns the thickness reading for the requested sensor.

Parameters: . . . . Sensor Number

Example: . . . . . . To Get Sensor 1 thickness, send: N1

The return string is of the form: 1.000

5.3.16 Get Output Thickness

Command: . . . . . O

Description: . . . . Returns the average thickness of all sensors assigned to the

requested output.

Parameters: . . . . Output Number

Example: . . . . . . To Get Output 1 thickness send: O1

The return string is of the form: 1.000

5.3.17 Get Sensor Frequency/Crystal Life

Command: . . . . . P

Description: . . . . Returns the frequency of the requested sensor.

Parameters: . . . . Sensor Number

Example: . . . . . . To Get Sensor 1 frequency, send: P1

The return string is of the form: 5543210.00

Command: . . . . . PA

Description: . . . . Returns the status, frequency, and crystal life of the requested

sensor.

Parameters: . . . . Sensor Number

Advertising