23 start download/upload session, 24 stop download/upload session, 4 crc examples – INFICON SQC-310 Thin Film Deposition Controller User Manual

Page 98

Advertising
background image

5 - 18

IP

N 07

4-

55

0-

P1

B

SQC-310 Operating Manual

Parameters:
1 Alarm: MinRate&MaxPower

15 Alert: Min Power

2 Alarm: MaxRate&MinPower

16 Alert: Logic Statement Action

3 Alarm: ShutterDelayError

17 Attention: Crystal Failure

4 Alarm: Crystal Failure

18 Attention: Xtal Failed & Xtal Switched

5 Alarm: Source Timeout

19 Attention: Rate Deviation

6 Alarm: Sensor Timeout

20 Attention: Max Power

7 Alarm: No Sensors Enabled

21 Attention: Min Power

8 Alarm: In Time Power

22 Attention: Manually Move Source

9 Alarm: Rate Deviation

23 Attention: Manually Move Sensor

10 Alarm: Invalid Pocket

24 Attention: Interlock

11 Alarm: Invalid Crystal

25 Attention: Logic Statement Action

12 Alarm: Logic Sttmnt Action
13 Alert: Rate Deviation
14 Alert: Max Power

Format:. . . . . . . . VA? [Parameter1] [Parameter2] …

Example: . . . . . . VA? 1 2 3

Returns: A1,0 2,0 3,1

5.3.23 Start Download/Upload Session

Command: . . . . . XSTART

Description: . . . . Starts a upload/download session & places in the instrument in

remote mode. The instrument must be Stopped in order to start
an upload/download session.

Parameters:

5.3.24 Stop Download/Upload Session

Command: . . . . . XSTOP

Description: . . . . Stops an upload/download session & kicks the instrument out of

remote mode.

Parameters:

5.4 CRC Examples

In this section you will find examples of code for calculating the CRC in Visual
Basic, Java, and C++. Instructions for calculating the CRC are located in

section

5.2

.