4 connection/wiring of the controller, Connection/wiring of the controller, 4connection/wiring of the controller – Lenze E84AVSCx 8400 StateLine C User Manual

Page 11

Advertising
background image

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

11

4

Connection/wiring of the controller

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4

Connection/wiring of the controller

[4-1]

Wiring of the power and motor terminals of 230V devices (on the left) and 400V devices (on the right)

[4-2]

Wiring of the control terminals / preconfigured assignment (Lenze setting)

J>

PE

Rb1 Rb2

U

V

W

X105

T1 T2

X106

"

M

3~

PTC

"

R

b

"

M

3~

"

"

Rb1 Rb2

+

+

+

+

E84AVSCxxxx ...

2

1/N/PE AC 230 V

PE

L1

N

PE

F1

K

Z

L1 N

X100

F2

K

K

O

I

R

b

J

+

J>

PE

Rb1 Rb2

U

V

W

X105

T1 T2

X106

"

M

3~

PTC

"

R

b

"

M

3~

"

"

Rb1 Rb2

+

+

+

+

E84AVSCxxxx ...

4

PE

3/PE AC 400 V/500 V

L1
L2
L3

N

PE

F1…F3

K

Z

L1

+UG

L2 L3

-UG

X100

F4

K

K

O

I

R

b

J

+

X3 - Analog terminals

A1U Main speed setpoint

10 V ≡ 100 % reference speed ≡ 1500 rpm

(applies to 4-pole asynchronous motors)

O1U Actual speed value

10 V ≡ 100 % reference speed ≡ 1500 rpm

X4 - Digital terminals

24E External supply - control electronics (optional)
RFR Controller enable / Reset of error message

DI1 Fixed speed setpoint 1 (40 % of the reference speed)
DI2 Fixed speed setpoint 2 (60 % of the reference speed)
DI3 Manual DC-injection braking
DI4 Change of direction of rotation

DO1 Status "Drive is ready"

X101 - relay output

COM/NO Status "Error is pending"

&20
1&
12

$5
$8
$,
*$
28

(
,
5)5
',
',
',
',
'2
*,2

*1'$

9P$

*1',2

;

;

;

9

9

N

9'&

($96&[[[[[